Brand Name : LABNOVATION

Certification : ISO13485, ISO9001,CE

Place of Origin : China

MOQ : 500 Pieces

Price : US$8-12/Pieces

Payment Terms : D/A, D/P, T/T

Supply Ability : 500000/Day

Delivery Time : 10 work day

Packaging Details : 20L, 50L,500ML

Model Number : L-8547196

Expiry : 24 Months

Usage : Medical, Clinical Experiments

Type : Hematology Reagent

High Light : Blood Test Reagents, Medical Lab Reagents

State : Liquid

Purity : >99%

Contact Now

Hematology Reagent For Coulter Gen.S , LH-750, LH-780, DXH-800 Analyzers High Quality Reagents

Intended Use

To be used for blood cell counting, sizing, and WBC, RET differentiation, hemoglobin determination on Coulter GEN.S , LH-750, LH-780, DxH-800 hematology analyzers. This product is for In Vitro Diagnostic Use only.

Procedures
  • Remove all the reagent aspiration tubes from the currently used reagent boxes
  • Wipe the tube’s surface with a lent free tissue, and then rinse with distilled water.
  • Put all the tubes into the boxes and/or bottles of Labnovation reagents.
  • Run at least 50 backgrounds. Check for the acceptable values. At first high background counts can be seen, that should lower to normal after a few runs.
  • Run all three levels of a dedicated commercial control. Check for the acceptable values.
  • Recalibrate the unit if necessary.
Coulter GenS LH750 LH780 DXH800 Hematology Reagent
Precautions
  • Re-calibration is recommended when changing the origin of the reagents.
  • It is not recommended using different brands of solutions together on one unit of analyzer.
  • Do not ingest. Avoid contact with skin and eyes.
  • Skin contact: Flush with plenty of water.
  • Eyes contact: Flush with plenty of water. Obtain immediate medical attention.
  • This kit is for professionals and in vitro diagnostic use only.

Specification

L-8547196 RET STAIN 380 ML
L-8547197 RET LYSE 1900 ML
L-8546983 LYSE DIFF 1 L
L-8546733 ISOTONIC DILUENT 20 L
L-8546930 E-CLEANER 5 L

KIT COMPOSITION

RET STAIN

New Methylene Blue 0.06%

RET LYSE Sulfuric Acid 0.15%
LYSE DIFF

Quaternary Ammonium Salt<10%, Sodium Lauryl Sulfate<1.5%

ISOTONIC DILUENT

NaCl≤9.4%, Buffer≤1.6%, Anti-Microbial Agent≤1%

E-CLEANER Buffer<0.3%, Proteolytic Enzyme<0.2%
Coulter GenS LH750 LH780 DXH800 Hematology Reagent
Coulter GenS LH750 LH780 DXH800 Hematology Reagent
Coulter GenS LH750 LH780 DXH800 Hematology Reagent

APPLICABLE INSTUMENT

  • For use with Beckman coulter GEN.S , LH-750, LH-780, DxH-800 hematology analyzers.
Advantage
  • One source for all brands of analyzer
  • Reagents for both 3-parts and 5-parts
  • Ready-to-use final products and bulk OEM reagents
  • ISQ13485:2003 and ISO9001:2008 certified
  • CE marked, FDA cleared
  • Well-established brand used by thousands of lab in 95 countries
  • High quality, high performance and high fidelity of correlations with original brand.

Storage

  • Store the product at 5-35℃ in a dust free place with good ventilation. Temperature outside the range may damage the product.
  • The open vial life of the product is 30/60 days. Unused reagents should be discarded after 30/60 days. Do not mix residual with a new carton.

Product Tags:

DXH800 Hematology Reagent

      

LH780 Hematology Reagent

      

Coulter GenS Hematology Reagent

      
Wholesale Coulter GenS LH750 LH780 DXH800 Hematology Reagent from china suppliers

Coulter GenS LH750 LH780 DXH800 Hematology Reagent Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Labnovation Technologies, Inc.
*Subject:
*Message:
Characters Remaining: (0/3000)